Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Tipo de estudo
Intervalo de ano de publicação
1.
J Appl Clin Med Phys ; 25(2): e14189, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37917885

RESUMO

PURPOSE: We performed scalp-avoidance whole-brain irradiation with volumetric-modulated arc therapy (SAWB-VMAT) as a component of craniospinal irradiation. In SAWB-VMAT with two coplanar arcs, radiation oncologists and medical physicists sometimes experience difficulty in reducing the dose to the scalp to below the cut-off equivalent dose in 2 Gy per fraction (assuming α/ß = 2) to 50% (EQD50%scalp ). To investigate the advantage of adding coplanar or non-coplanar arcs in reducing the dose to the scalp in SAWB-VMAT, we conducted a planning study to compare the EQD50%scalp , the dose to other organs at risk (OARs), and target coverage in VMAT with two coplanar arcs (Co2arcVMAT), VMAT with three coplanar arcs (Co3arcVMAT), and VMAT with two coplanar and two non-coplanar arcs (NcVMAT). METHODS: Co2arcVMAT, Co3arcVMAT, and NcVMAT plans were created for 10 pediatric patients with medulloblastoma. The planned target volume (PTV) included the regions of the whole brain, cervical spinal cord, cerebrospinal fluid space, and intervertebral foramen. The EQD50%scalp was evaluated separately for four areas (top, back, left, and right) in each case. The prescribed dose for the PTV was 35.2 Gy in 22 fractions. RESULTS: The median EQD50%scalp of the top area was 21.9 , 22.1 , and 18.3 Gy for Co2arcVMAT, Co3arcVMAT, and NcVMAT, respectively. The EQD50%scalp of the top area was significantly reduced in NcVMAT compared to those in Co2arcVMAT and Co3arcVMAT (p < 0.05). The median EQD50%scalp of the top area for NcVMAT was < 19.9 Gy, which is the cut-off dose for severe permanent alopecia. There were no significant differences in EQD50%scalp in the three other areas, the dose to other OARs, or the dose coverage of PTV among the three techniques. CONCLUSION: NcVMAT could reduce the EQD50%scalp of the top area below the cut-off dose of 19.9 Gy. NcVMAT appears to be a promising treatment technique for SAWB-VMAT.


Assuntos
Neoplasias Cerebelares , Meduloblastoma , Radioterapia de Intensidade Modulada , Humanos , Criança , Meduloblastoma/radioterapia , Meduloblastoma/etiologia , Dosagem Radioterapêutica , Redução da Medicação , Couro Cabeludo , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Órgãos em Risco/efeitos da radiação , Encéfalo , Neoplasias Cerebelares/etiologia
3.
Jpn J Radiol ; 40(10): 987-994, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36057071

RESUMO

The prognosis of patients with brain metastases has dramatically improved, and long-term tumor control and reduction of the risk of late toxicities, including neurocognitive dysfunction, are important for patient quality of life. Stereotactic irradiation for multiple brain metastases, rather than whole-brain radiotherapy, can result in high local control rate with low incidence of neurocognitive deterioration and leukoencephalopathy. Recent advances in radiotherapy devices, treatment-planning systems, and image-guided radiotherapy can realize single isocenter stereotactic irradiation for multiple brain metastases (SI-STI-MBM), in which only one isocenter is sufficient to treat multiple brain metastases simultaneously. SI-STI-MBM has expanded the indications for linear accelerator-based stereotactic irradiation and considerably reduced patient burden. This review summarizes the background, methods, clinical outcomes, and specific consideration points of SI-STI-MBM. In addition, the prospects of SI-STI-MBM are addressed.


Assuntos
Neoplasias Encefálicas , Radiocirurgia , Infecções Sexualmente Transmissíveis , Neoplasias Encefálicas/patologia , Humanos , Aceleradores de Partículas , Qualidade de Vida , Dosagem Radioterapêutica
4.
J Radiat Res ; 2021 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-34604907

RESUMO

In the delivery of stereotactic radiosurgery (SRS) by linear accelerator (LINAC), dynamic conformal arc therapy (DCAT) with non-coplanar beams is conventionally used. However, volumetric modulated arc therapy (VMAT) can improve target conformity, thereby decreasing the dose to organs at risk by inversed planning methods, but few studies have directly compared DCAT and VMAT with and without non-coplanar beams in patients with single brain metastasis. We therefore conducted a planning study to compare the dose distribution in DCAT, VMAT using only a coplanar arc (CoVMAT) and VMAT with non-coplanar arcs (NcVMAT) in the treatment of single brain metastasis. DCAT, CoVMAT and NcVMAT plans were created for 15 patients. The three modalities were compared in terms of target conformity, target coverage, the dose to normal brain tissue, monitor units (MUs) and beam-on time. Both conformity indices (RTOG-CI and IP-CI) as well as the D98% of the gross target volume (GTV) were significantly better in the NcVMAT plans than in the DCAT plans. Comparisons of the doses to normal brain tissue revealed that the V20Gy, V15Gy, V12Gy, V10Gy and V5Gy were significantly smaller in the NcVMAT plans than in the plans based on the other two modalities. The MUs of the DCAT and NcVMAT plans were larger than those of the CoVMAT plans, and the beam-on time was longer in the NcVMAT and CoVMAT plans than in the DCAT plans. Compared to the CoVMAT and DCAT plans, NcVMAT plans significantly improved target conformity and reduced the doses to normal brain tissue at V20Gy, V15Gy, V12Gy, V10Gy and V5Gy.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA